8 Dry/Wet contact Digital Input Channels and 8 source-type Digital Output PoE Module, web browser configurable, allows users to implement IF-Then Else If type control logic and communicable over Modbus TCP. Operating temperatures of -25°C to +75°C.
Features
Developed by ICP DAS, WISE (Web Inside, Smart Engine), is a user-friendly yet powerful controller for remote logic control and monitoring in various industrial applications. WISE-7555M is designed with a web site interface allowing users to implement IF-THEN-ELSE control logic on controller with no programming required.
With the integration of the IF-THEN-ELSE rule engine, WISE-7555M provides powerful functions such as I/O Monitoring/Control, Counter, Timer, Schedule, E-mail sending & CGI Command sending for numerous industrial applications. WISE-7555M also supports Modbus TCP and MQTT protocols to make seamless integration with SCADA, IT and IoT (Internet of Things) system.
WISE-7555M is equipped with 8 Dry/wet contact digital input channels and 8 source-type digital output channels. It features optical isolation for 2500 VDC of transient overvoltage protection but doesn’t provide channel-to-channel isolation. It can safely be used in applications where hazardous voltages are present. WISE-7555M follows IEEE 802.3af- compliant Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs. In additional to this, WISE-7555M also has a built-in two-port Ethernet switch to implement daisy-chain topology. The cabling is much easier and total costs of cable and switch are significantly reduced.
- Runs on browsers, no extra software tool is required.
- No more programming, Web pages provided for control logic editing.
- IF-THEN-ELSE logic rules execution ability.
- Built-in I/O(DI: 8 Channels; DO: 8 Channels)
- Support I/O Monitoring/Control, Counter, Timer, Email sending and CGI Command sending operations.
- Modbus TCP Protocol for SCADA System Integration.
- IEEE 802.3af-compliant Power over Ethernet (PoE).
- 2-port Ethernet Switch for Daisy-Chain Topology.
- Support Schedule operation
- MQTT Protocol for IT & IoT(Internet of Things) System Integration.
Specifications
Hardware Specifications
Display
Channels
8
Contact
Dry +Wet
Sink/Source (NPN/PNP)
Dry: Source
Wet: Sink/Source
Wet Contact
On Voltage Level
+10 VDC to +50 VDC
Off Voltage Level
+4 VDC Max.
Dry Contact
On Voltage Level
Close to GND
Off Voltage Level
Open
Input Impedance
10 kΩ
Counters
Max. Counts
16-bit (65535)
Max. Input Frequency
50 Hz
Min. Pulse Width
10 ms
Overvoltage Protection
+70 VDC
Effective Distance
500 M Max.
Digital Output
Channels
8
Type
Isolated Open Collector
Sink/Source (NPN/PNP)
Source
Max. Load Current
650 mA/channel at 25°C
Load Voltage
+10 VDC to +40 VDC
Overvoltage Protection
47 VDC
Overload Protection
-
Short-circuit Protection
Yes
Communication
Ethernet Port
2 x RJ-45, 10/100 Base-TX, Swtich Ports
PoE
Yes
Protocol
Modbus TCP, MQTT
LED Indicators
for System Running
Yes
for Ethernet Link/Act
Yes
for I/O Channel Status
Yes
for PoE Power
Yes
LED Indicators
I/O
2500 VDC
EMS Protection
ESD (IEC 61000-4-2)
±4 kV Contact for Each Terminal and ±8 kV Air for Random Point
EFT (IEC 61000-4-4)
±2 kV for Power Line
Surge (IEC 61000-4-5)
±2 kV for Power Line
Power
Reverse Polarity Protection
Yes
Powered from Terminal Block
12 to 48 VDC
Powered from PoE
Yes, IEEE 802.3af, Class1
Consumption
3.7 W (Max.)
Mechanical
Dimensions (L x W x H)
120mm x 97mm x 42mm
Installation
Wall mounting
Environment
Operating Temperature
-25°C to +75°C
Storage Temperature
-30°C to +80°C
Humidity
10 to 90% RH, non-condensing
Software Specifications
Functions
Rule Configuration Website
Access Web server on WISE controllers to edit and upload logic rules through web browser.
72 IF-THEN-ELSE Logic Rules
3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
48 Internal Registers
Hold temporary variables and read/write data
24 Timers
Delay / Timing functions.
24 Schedules
Setup prescheduled routine tasks.
24 Emails
Send Email messages to pre-set Email receivers.
24 CGI Commands
Send pre-set CGI commands.
24 Recipes
Set up THEN/ELSE action groups.
8 P2P remote modules
Set up the connection information for the remote WISE modules.
Modbus TCP Protocol
Real time control and monitoring I/O channels and system status of controllers via SCADA software.
MQTT Protocol
Real time message publish/subscribe mechanism for I/O channels and system status via IT/IoT software.
IF Conditions
DI Channel
ON, OFF, ON to OFF, OFF to ON, Change
Internal Register
=, >, <, >=, <= (value)
DI Counter
DO Counter
=, >, <, >=, <= (value), Change
Timer
Timeout, Not Timeout
Schedule
In Range, Out of Range
P2P
DI, AI, DI counter, DO counter, IR
Rule Status
Enable, Disable
THEN / ELSE Actions
DO Channel
ON, OFF, Pulse Output
Internal Register
Change the value
DI Counter
DO Counter
Reset
Timer
Start, Reset
Schedule
Enable, Disable
Email
MQTT message
CGI Commands
Send
Recipe
Execute
P2P
DO(On/Off), AO, IR
Rule Status