VXC-182iAU
Universal PCI Bus, Serial Communication Board with 1 Isolated RS-422/485 port and 1 RS-232 port (RoHS)
Features
The VXC-182iAU serial card is equipped with two communication ports: RS-422/485 and RS-232 port. It can be configured as either RS-485 for half-duplex or RS-422 for full-duplex communication. Both configuration supports speed up to 115200 bps allowing information to be transmitted over a long distance communication link.
Users can specify a COM port number manually by setting DIP switch, or let the driver choose an available number automatically. The driver provides a maximum of 128 KB software FIFO for each COM port under Windows, allowing for large file transmission.
The data lines of each serial ports on i version VXC cards is designed with photo couplers. The on-board photo couplers use a short optical transmission path to transfer a signal between elements of a circuit, and keep the data lines electrically isolated. This helps eliminate ground loops, common mode voltages and block voltage spikes, provide electrical isolation, and offer significant protection from serious over-voltage conditions in one circuit affecting the other.
In harsh industrial environments, the on-board ESD protection component (for i version) protects the computer and equipment from the sudden and momentary electric current by preventing charge away from the circuit.
The serial communication card are designed for use with intelligent devices like bar code reader, serial printers, intelligent sensors, instrumentation equipment, computers and almost any device with an RS-232 port.
- Provides 1 isolated RS-422/485 port and 1 RS-232 port
- Built-in COM-Selector
- +/-4 kV ESD Protection
- 128 KB Software Buffer (max.) for Each COM Port Under Windows
- Self-Tuner Inside
- Supports 3.3 V/5 V PCI bus, Plug and Play
- 128-byte Hardware FIFO for Each Port
- Short Card Design
- 2500 VDC Isolation Isolated RS-422/485 port
Software
- Windows NT4/2000 drivers for VXC series.
- Drivers for 32-bit Windows XP/2003/2008/7/8/10
- Drivers for 64-bit Windows XP/2003/2008/7/8/10
- Driver for Linux
Applications
- Industrial Machinery
- Building Automation
- Restaurant Appliances
- Laboratory Equipment & Research
- Industrial Communication
Specifications
Communication Port
COM1
RS-422/485
The RS-422 and RS-485 cannot be used simultaneously
RS-422
TxD+, TxD-, RxD-, RxD+, RTS+, RTS-, CTS+, CTS-, GND
RS-485 - 2-Wire
Data+, Data-, GND
RS-485 - Bias Resistor
Yes, 1 KΩ
RS-485 - Node
256 (max.)
UART
16C950 compatible
Baud Rate
50 - 115200 bps
Data bit
5, 6, 7, 8
Stop bit
1, 1.5, 2
Parity
None, Even, Odd, Mark, Space
FIFO
Internal 128 bytes
Isolated
2500 VDC for RS-422/485 port
General
Bus Type
Universal PCI, 3.3 V and 5 V, 33 MHz, 32-bit, Plug and Play mechanism
COM-Selector
Yes (8-bit DIP switch)
Connector
2 x DB9 (Male)
Power Consumption
200 mA @ 5 V
Operating Temperature
0°C ~ +60°C
Storage Temperature
-20°C ~ +70°C
Humidity
0 ~ 90% RH, non-condensing
Dimensions (L x W x D)