SDR-120-12
12 V / 10 A, 120 W Single Output Industrial DIN Rail Power Supply with PFC Function with operating temperature range of -25°C ~ +70°C (-13°F ~ 158°F).
References & Support
Features
Specifications
Output
|
|
DC Voltage
|
12 V
|
Rated Current
|
10 A
|
Current Range
|
0 ~ 10 A
|
Rated Power
|
120 W
|
Peak Current
|
15 A
|
Peak Power - Note 6
|
180 W (3 sec.)
|
Ripple & Noise (max.) |
100mVp-p
|
Voltage Adj. Range | 12 ~ 14 V |
Voltage Tolerance | ±1.0% |
Line Regulation | ±0.5% |
Load Regulation | ±1.0% |
Setup, Rise Time | 1500ms, 60ms/230 VAC 3000ms, 60ms/115 VAC at full load |
Hold Up Time (Typ.) | 20ms/230 VAC 20ms/115 VAC at full load |
Input
|
|
Voltage Range | 88 ~ 264 VAC 124 ~ 370 VDC |
Frequency Range | 47 ~ 63Hz |
Power Factor (Typ.) | 0.93/230 VAC 0.99/115 VAC at full load |
Efficiency (TyINPUT p.) - Note. 8 | 89% |
AC Current (Typ.) | 1.4 A/115 VAC 0.7 A/230 VAC |
Inrush Current (Typ.) | 35 A/115 VAC 70 A/230 VAC |
Leakage Current | <1 mA/240 VAC |
Protection
|
|
Overload | Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage with auto-recovery |
>150% rated power, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 3 seconds | |
Over Voltage
|
14 ~ 17V
|
Protection type : Shut down o/p voltage with auto-recovery | |
Over Temperature
|
95°C ±5°C (TSW : detect on heatsink of power switch)
|
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | |
Function | |
DC OK Realy Contact Ratings (max.) | 60 Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load |
Environment
|
|
Working Temperature - Note. 5 | -25 ~ +70°C (-13°F ~ 158°F) (Refer to "Derating Curve") |
Working Humidity | 20 ~ 95% RH non-condensing |
Storage Temperature, Humidity | -40 ~ +85°C , 10 ~ 95% RH |
Temperature Coefficient | ±0.03%/°C (0 ~ 50°C) |
Vibration
|
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
|
Safety & EMC (Note 4)
|
|
Safety Standards | UL508, TUV EN60950-1 approved |
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25°C / 70% RH |
EMC Emission | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
EMC Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, SEMI F47, GL approved |
Other
|
|
MTBF | 289.9Khrs min. MIL-HDBK-217F (25 °C) |
Dimensions | 40 mm x 125.2mm x 113.5mm (W x H x D) |
Packing
|
0.67Kg; 20pcs/4.4Kg/1.16CUFT
|
Note
|
|
|