Download Now

Enter your information or login to view the document.


×
6 Analog Input Channel RTD Input Data Acquisition Module, communicable over Modbus RTU and RS-485. Supports operating temperatures between -25 to 75°C.

M-7015

6 Analog Input Channel RTD Input Data Acquisition Module, communicable over Modbus RTU and RS-485. Supports operating temperatures between -25 to 75°C.

  Price:  $489.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

intro

The M-7015 device is a network data acquisition and control modules that support Modbus RTU. They can be remotely controlled using a set of commands called DCON protocol. With the Modbus RTU protocol, it can easily communicate with most popular SCADA/ HMI software and PLCs.


  • 6 channels of RTD module
  • Communication Interface: ModBus Protocol
  • Individual Channel Configurable
  • Wire Opening Detection
  • Input channels : 6
  • Input Type: Supports 2/3 wire RTD
  • Din Rail Mount

Specifications

Analog Input
Input Channels 6
Input Type RTD
Wire connection 2/3 wire
RTD Type Pt100, Pt1000, Ni120, Cu100, Cu1000
Resolution 16-bit
Sampling Rate 12 samples/ second (Total)
Accuracy +/-0.05%
-3dB BandWidth 5.24Hz
Zero drift +/-20uV/°C
Span drift +/-25ppm/°C
Common Mode Rejection Typical 86dB
Normal Mode Rejection 100 dB
Voltage Input Impedance >1M Ohms
Open Wire Detection Yes
Individual Channel Configurable Yes
4KV ESD Protection Yes, Contact for each terminal.
Intra-module Isolation, Field to Logic 3000 VDC
Interface
Interface RS-485
Format N, 8, 1
Baud Rate 1200 ~ 115200bps
LED Display
1 LED as Power/ Communication indicator
Power
Input +10 to +30 Vdc
Power Consumption 1.1W
Protocol
Support Modbus and DCON Protocol Yes
Watchdog Yes, Module, Communication (Programmable over DCON) firmware version B202 and later
Environment
Operating temperature -25 to 75°C
Storage temperature -40 to 85°C
Humidity 5 to 95% RH, non-condensing
NOTE: We recommend to chose M-7015P for long distance RTD Line.

RTD Type Setting (TT)

Type Code RTD Type Temperature Range °C
20 Platinum 100, α= 0.00385 -100 ~ 100
21 Platinum 100, α= 0.00385 0 ~ 100
22 Platinum 100, α= 0.00385 0 ~ 200
23 Platinum 100, α= 0.00385 0 ~ 600
24 Platinum 100, α= 0.003916 -100 ~ 100
25 Platinum 100, α= 0.003916 0 ~ 100
26 Platinum 100, α= 0.003916 0 ~ 200
27 Platinum 100, α= 0.003916 0 ~ 600
28 Nickel 120 -80 ~ 100
29 Nickel 120 0 ~ 100
2A Platinum 1000, α= 0.00385 -200 ~ 600
2B Cu 100 at 0°C,α= 0.00421 -20 ~ 150
2C Cu 100 at 25°C,α= 0.00427 0 ~ 200
2D Cu 1000 at 0°C,α= 0.00421 -20 ~ 150
2E Platinum 100, α= 0.00385 -200 ~ 200
2F Platinum 100, α= 0.003916 -200 ~ 200
80 Platinum 100, α= 0.00385 -200 ~ 600
81 Platinum 100, α= 0.003916 -200 ~ 600
82 Cu 50 at 0°C -50 ~ 150
83 Nickel 100 -60 ~ 180

References and Support

Customer Reviews (0)

Be the first to leave a review.

Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left