We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

References & Support


Features

The DN-800V series are voltage input attenuator. The maximum input range is from ±80 V to +/- 600 V and can be attenuated to ±10 V. The "I" version provide 3000 VDC intra-modules isolation and 3000 VDC channel to channel isolation to avoid the noise interference from inputs to outputs or channel to channel. It can be used with the analog input modules such as I-7017 and I-87017 etc. to measure the high voltage.

RoHS WEEE
  • AC/DC Source Input
  • High Voltage Input Measurement
  • Linear Attenuation Ratio
  • High Input Impedance
  • Channel to Channel Isolation for DN-848VI-10V,
    DN-848VI-80V, DN-848VI-150V and DN-843VI-600V
  • Channel to Channel Isolation for DN-848VI-10V,
    DN-848VI-80V and DN-848VI-150V
  • 4 kV ESD Protection
  • 3 kV Surge Protection
  • RoHS Compliance
  • Operating Temperature: -25 °C ~ +75 °C
  • Easily wire connection

Applications

DN-848VI_app

Specifications

General
Channel 8
Input Type AC/DC Voltage
Input Range +/- 150 Vpp
Output Range +/- 10 Vpp
Accuracy 1% of FSR
Chanel to Channel Isolation Yes, 3000 VDC
Bandwidth 30 KHz
Input Impedance > 1 MΩ
Intra-module Isolation, Input to Output 3000 VDC
EMS Protection
ESD (IEC 61000-4-2) +/- 4 kV contact for power line, input and output channels , +/- 8 kV air for random point
Surge (IEC 61000-4-5) +/- 3 kV for power liner
Power Input
Input Range +10 ~ +24 VDC
Power Consumption 9.2 W
Mechanical
Dimensions (W x L x H) 122 mm x 174 mm x 33 mm
Installation DIN-Rail Mounting
Environment
Operating Temperature -25 ~ +75°C
Storage Temperature -30 ~ +75°C
Humidity 10 ~ 90% RH, Non-condensing