Download Now

Enter your information or login to view the document.


×
Cellular Wireless Intelligent 3G Remote Terminal Controller with GPS, SMS and GPRS functions for remote monitoring applications.  Can be used for Vehicle Tracking.  Has 6 Digital Input, 2 Digital Output, and 1 Analog Input channel. Communicates over Modbus RTU, RS-485, RS-232, and GPRS networks. Supports operating temperatures from -25°C ~ +75°C (-13°F ~  +167°F). GT-540P-3GWA is phased out and replaced by GTP-541M.

GT-540P-3GWA

Cellular Wireless Intelligent 3G Remote Terminal Controller with GPS, SMS and GPRS functions for remote monitoring applications. Can be used for Vehicle Tracking. Has 6 Digital Input, 2 Digital Output, and 1 Analog Input channel. Communicates over Modbus RTU, RS-485, RS-232, and GPRS networks. Supports operating temperatures from -25°C ~ +75°C (-13°F ~ +167°F). GT-540P-3GWA is phased out and replaced by GTP-541M.

    Item Not Available  


Features

The GT-540P-3GWA has officially been phased out and will no longer be available. It has now been replaced by GTP-541M.

M2M solution for In-Vehicle monitoring - GT-540P

The GT-540P is a wireless intelligent Active 3G Remote Terminal Unit with GPS. It is ideal for remote monitoring applications. With the high performance 32 bit CPU, the GT-540P is suited for hard industrial environments. It features a 3G GPRS/GSM module, 6 digital inputs, 2 digital outputs, 1 analog input, 2 RS-232, 1 RS-485 and SD interface. It can be used in M2M application fields to transfer the local I/O or Modbus device’s data by GPRS by the defined period or DI/AI triggers. The local I/O and GPS data can also be stored in the SD card to become a remote data logger. For another communication path, the GT-540P offers the E-mail mode to transfer the data by E-mail via GPRS for users to choose. The simple I/O linkage function of the GT-540P can reach the real time control in the local field. It also supports Li-ion battery as another power source when the main power is failed temporarily. Therefore, the GT-540P is an ideal solution for environmental monitoring, remote device management and real time vehicle tracking and monitoring systems for M2M applications. Meanwhile, it is supplied with easy-to-use API and OPC server Software that streamline application development process, freeing system integrators from dealing with complex communication protocols of GPRS and the Internet.

 

GT-540AP

Applications

applications 1

applications 2

Features

  • Automatic/continuous GPRS Link Management
  • Supports Modbus RTU protocol to connect to Max 3 Modbus RTU devices via RS-485 port
  • Supports M2M OPC server for SCADA system
  • Easy-to-use API tool for users to develop their applications by various program development tools
  • Be the GPRS I/O devices
  • Support data transferring by E-mail
  • Support GPS function
  • Local I/O linkage function to make the simple local control
  • Support 3.7V Li-ion Battery backup
  • Power supply 10 ~ 30 VDC

Utility

ICP DAS provide graphic tool for users to configure GT-540P. The utility also can help users to test GT-540P in the Lab before they apply in the real site.

G-4500 Utility

Software Solutions

The M2M RTU center software with friendly Graphic interface is to manage the GPRS RTU products easily. Users can monitor the I/O data and status of GPRS RTU devise by the interface on PC. By using the GPRS RTU API tool and M2M RTU center software, any remote monitoring system can be achieved easily and efficiently. For SCADA system, the M2M.OPC server is provided to connect to SCADA by OPC interface.

software

Item
Web site
M2M RTU Center
M2M RTU series management software
M2M RTU Win32 API
M2M RTU development tool
NAPOPC.M2M DA Server
OPC Server for M2M RTU devices
EZ Data Logger
The small data logger software of ICP DAS
InduSoft SCADA
SCADA software
  • Easy to Establish GPRS Network Applications
    It is a big headache for engineers to establish the GPRS applications because the dynamic IP management is required. Applying the GT-540P and M2M RTU center software, the dynamic IP addresses can be managed between them. The remote GPRS RTU product would connect to M2M RTU Center automatically. Therefore, all remote GPRS RTU devices can be managed by single centralized M2M GPRS RTU Center software with a fixed IP address. 
    Moreover, there are M2M API tool and OPC server for engineers to develop the GPRS applications by VB, VC or SCADA development tools conveniently without any IP address management effort.
  • Active data transmission
    The GT-540P with active I/O transmission mechanism can raise the communication. Unlike the traditional poll communication, it would transfer the data by the defined time, DI trigger or AI hi/lo alarm. In addition to improve the way of communication, that can also reduce the AP effort.
  • Transfer data by e-mail
    Aside from the transferring data by the general communication with the M2M RTU center, users can choose the e-mail mode to send these data by e-mail over GPRS in the fixed time.
  • Modbus RTU device connectivity
    The GT-540P is built-in Modbus RTU protocol. That can make any Modbus RTU device connect to the GT-540P. By the way of GT-540, Modbus RTU devices can be used in GPRS remote system. The max Modbus RTU device can be connected to the GT-540P is three.
  • Simple Local I/O link Control
    There are I/O built-in GPRS RTU devices of ICP DAS. Therefore, these products can be the GPRS I/O devices. The local I/O data can be sent to the host PC, the I/O link function of them help users to do the simple control in local field. For example: the DI trigger or high/low AI alarm can driver the DO channel.
  • Built-in I/O Data Logging
    The GT-540P provides an external SD interface. These local I/O and Modbus data are recorded in SD memory card for one day in a single file.

How to Use

GT-540 use

Specifications

System
CPU
32 bit, 72 MHz
SRAM
64 Kbytes
Flash Memory
512 Kbytes
RTC
Gives time(sec, min, hour) & date, leap year compensation from 1980 to 2079
WDT(watchdog)
Yes
SD interface
2GB max.
Serial ports
COM1
RS-232 : TxD,RxD,GND for configuration
COM2
RS-485 : D2+, D2-
Digital Input
Input Channel
6
Input Type
Sink or Source, Isolated channel with common power or ground
Off Voltage Level
+1V max.
On Voltage Level
+3.5 ~ 24 VDC
Isolated Voltage
3750Vrms
Counters
6 (16 Bit, 5~40Hz), 
Min. Pulse Width : 5ms
Digital Output
Channels
2
Output Type
Open-Collector (NPN) (500mA@24VDC)
Load Voltage
+24 V max
Load Current
500 mA max
Isolated Voltage
3750Vrms
Analog Input
Channels
1
Resolution
12 bit
Input Range/Type
0 ~ 20 mA
GSM/GPRS system
GPRS/GSM
3G
GPRS multi-slot : class 10/8
GPRS mobile station : class B
GPRS class 10 : Max download speed 85.6 kbps
CSD max speed 14.4 kbps
Compliant to GSM phase 3
 -Class 4(2W @ 900 MHz)
 -Class 1(1W @ 1800/1900 MHz)
Coding schemes : CS 1, CS 2,CS 3,CS 4
GPS Interface
Support Channels
32
Sensitivity
Tracking = up to -159 dBm (with external LNA)
Cold start = up to -146 dBm (with external LNA)
Acquisition Time
Hot start (Open Sky) = 2 s(typical)
Cold start (Open Sky) = 36 s(typical)
Protocol Support
GPRMC format (NMEA 0183 version 3.01)
Power
Protection
Reverse polarity protection
Frame Ground Protection
ESD, Surge, EFT, Hi-Pot
Required Supply Voltage
+10 VDC ~ +30 VDC
with 600 mAh Li-ion battery backup
Mechanical
Casing
Plastic
Flammability
UL 94V-0 materials
Dimensions (W x L x H)
91 mm x 132 mm x 52 mm
Installation
DIN-Rail
Environmental
Operating Temperature
-25℃ ~ +75 ℃
Storage Temperature
-40℃ ~ +80 ℃
Ambient Relative Humidity
5 ~ 95% RH, non-condensing

References and Support

Customer Reviews (1)

November 30, -0001
R. Wilson
5/5

When I was asking what I should use for my remote monitoring project, they recommend this GT-540 for me. Now it's been working fine for two years and I would definitely recommend it.


Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left