Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking, with 3-channel Analog Input, 6-channel Digital Input/Counter, and 3-channel Power Relay Output. Supports Current Input and Voltage Input Types: +/-150 mV, +/-500 mV, +/-1 V, +/-5 V, +/-10 V +0 mA ~ +20 mA, +/-20 mA, 4 ~ 20 mA (jumper selectable).  Communicable over Modbus TCP and Modbus UDP.  Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.

ET-7202

Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking, with 3-channel Analog Input, 6-channel Digital Input/Counter, and 3-channel Power Relay Output. Supports Current Input and Voltage Input Types: +/-150 mV, +/-500 mV, +/-1 V, +/-5 V, +/-10 V +0 mA ~ +20 mA, +/-20 mA, 4 ~ 20 mA (jumper selectable). Communicable over Modbus TCP and Modbus UDP. Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.

  Price:  $549.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

The ET-7202 is a multi-function module with 3-channel analog inputs, 6-channel digital inputs and 3-channel relay outputs. It provides various programmable analog inputs (+/-150 mV, +/-500 mV, +/-1 V, +/-5 V, +/-10 V, +/-20 mA, 0 ~ 20 mA and 4 ~ 20 mA). Each analog input is allowed to configure a proper range with 240 Vrms high voltage protection. Each analog input can be programmed to accept current or voltage as input/output depending upon the position of corresponding jumper. The ET-7202 is fully RoHS compliant and has qualification for 4 kV ESD protection as well as 2500 VDC intra-module isolation.

  • Built-in Web Server
  • Web HMI
  • Support for both Modbus TCP and Modbus UDP Protocols
  • Communication Security
  • 2-port Ethernet Switch for Daisy-Chain Topology
  • Dual Watchdog
  • Wide Operating Temperature Range: -25 ~ +75°C
  • I/O Pair Connection
  • Built-in I/O
    • AI: 3 Channels with 240 Vrms Overvoltage Protection
    • DI/Counter: 6 Channels
    • Power Relay: 3 Channels

Applications

Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote Diagnosis, Testing Equipment.

Daisy-Chain Ethernet Cabling

The ET-7200/PET-7200 Series has a built-in two-port Ethernet switch to implement daisy-chain topology. The cabling is much easier and total costs of cable and switch are significantly reduced.

application2

LAN Bypass

LAN Bypass feature guarantees the Ethernet communication. It will automatically active to continue the network traffic when the ET-7200/PET-7200 looses its power.

application3

Communication Security

Account and password are needed when logging into the web server. An IP address filter is also included, which can be used to allow or deny connections with specific IP addresses.

Support for both Modbus TCP and Modbus UDP Protocols

The Modbus TCP, Modbus UDP slave function on the Ethernet port can be used to provide data to remote SCADA software.

Built-in I/O

Various I/O components are mixed with multiple channels in a single I/O module, which provides the most cost effective I/O usage and enhances performance of the I/O operations.

Dual Watchdog

The Dual Watchdog is consists of a Module Watchdog and a Communication Watchdog. The action of AO,DO are also associated to the Dual Watchdog.
Module Watchdog is a built-in hardware circuit to monitor the operation of the module and will reset the CPU if a failure occurs in the hardware or the software. Then the Power-on Value of AO,DO will be loaded.
Communication Watchdog is a software function to monitor the communication between the host and the I/O module. The timeout of the communication Watchdog is proprgrammable, when the I/O doesn't receive commands from the host for a while, the watchdog forces the AO,DO to pre-programmed Safe Value to prevent unpredicatable damage of the connected devices.

Highly Reliable Under Harsh Environment

  • Wide Operating Temperature Range: -25 ~ +75°C
  • torage Temperature: -30 ~ +80°C
  • Humidity 10 ~ 90% RH (Non-condensing)

I/O Pair Connection

This function is used to create a AI/DI to AO/DO pair through the Ethernet. Once the configuration is completed, the I/O module can poll the status of remote AI/DI devices and then use the Modbus TCP protocol to continuously write to a local AO/DO channels in the background.

application4 application5

Power-on Value and Safe Value

Besides setting by the set AO,DO commands, the AO,DO can be set under two other conditions.
Power-on Value: The Power-on Value is loaded into the AO,DO under 3 conditions: Power-on, reset by Module Watchdog, reset by reset command.
Safe Value: When the Communication Watchdog is enabled and a Communication Watchdog timeout occurs, the “safe value” is loaded into the AO,DO.

application6

Specifications

Software
Built-In Web Server Yes
Web HMI Yes
I/O Pair Connection Yes
Communication
Ethernet Port 2 x RJ-45, 10/100 Base-TX, Swtich Ports
PoE -
Protocol Modbus TCP, Modbus UDP
Security ID, Password and IP Filter
Dual Watchdog Yes, Module (0.8 seconds), Communication (Programmable)
LED Indicators
for System Running Yes
for Ethernet Link/Act Yes
for DI/DO status Yes
for PoE Power -
2 Way Isolation
Ethernet 1500 VDC
I/O 2500 VDC
EMS Protection
ESD (IEC 61000-4-2) ±4 kV Contact for Each Terminal and ±8 kV Air for Random Point
EFT (IEC 61000-4-4) ±2 kV for Power Line
Surge (IEC 61000-4-5) ±2 kV for Power Line
Power
Reverse Polarity Protection Yes
Powered from Terminal Block 12 ~ 48 VDC
Powered from PoE -
Consumption 4.5 W
Mechanical
Dimensions (W x L x H) 76 mm x 120 mm x 38 mm
Installation DIN-Rail or Wall mounting
Environmental
Operating Temperature -25 ~ +75 °C
Storage Temperature -30~ +80 °C
Humidity 10 ~ 90% RH, non-condensing

I/O Specifications

Analog Input
Channels 3 (Differential)
Type +/-150 mV, +/-500 mV, +/-1 V, +/-5 V, +/-10 V +0 mA ~ +20 mA, +/-20 mA, 4 ~ 20 mA (jumper selectable)
Individual Channel Configuration Yes
Resolution 16-bit
Sampling Rate Normal Mode 10 Samples/Second (Total)
Fast Mode 50 Samples/Second (Total)
Accuracy Normal Mode +/-0.1%
Fast Mode +/-0.5% or better
Zero Drift +/-20 μV/°C
Span Drift +/-25 ppm/°C
Overvoltage Protection 240 Vrms
Overcurrent Protection 50 mA max. at 110 VDC/VAC max.
Input Impedance Voltage 2 MΩ
Current 125 Ω
Common Mode Rejection 86 dB Min.
Normal Mode Rejection 100 dB
Open Wire Detection Yes, for 4 ~ 20 mA only
Virtual Channel to Channel Isolation +/-400 VDC
Digital Input/Counter
Channels 6
Contact Wet Contact
Sink/Source (NPN/PNP) Sink/Source
On Voltage Level +10 VDC ~ +50 VDC
Off Voltage Level +4 VDC Max.
Input Impedance 10 KΩ, 0.5W
Counters Channels 6
Max. Count 4,294,967,285 (32 bits)
Max. Input Frequency 100 Hz
Min. Pulse Width 5 ms
Overvoltage Protection +70 VDC
Power Relay
Channels 3
Type Power Relay, Form A (SPST N.O.)
Operating Voltage Range 250 VAC/30 VDC
Max. Load Current 5.0A/channel at 25°C
Operate Time 6 ms (Typical)
Release Time 3 ms (Typical)
Electrical Life ( Resistive load ) VDE: 5 A @ 250 VAC 30,000 ops (10 ops/minute) at 75°C.
5 A @ 24 VDC 70,000 ops (10 ops/minute) at 75°C.
UL: 5 A @ 250 VAC/24 VDC 6,000 ops.
3 A @ 250 VAC/24 VDC 100,000 ops.
Mechanical Life 20,000,000 ops. at no load (300 ops./minute).
Intra-module Isolation, Field to Logic 3750 VDC
Power-on Value Yes, Programmable
Safe Value Yes, Programmable

References and Support

Customer Reviews (0)

Be the first to leave a review.

Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left