Download Now

Enter your information or login to view the document.


×
CO/CO2/Temperature/Humidity/Dew Point Data Logger (IP65 enclosure)

DL-303-IP65

CO/CO2/Temperature/Humidity/Dew Point Data Logger (IP65 enclosure)

  Price:  $1,149.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

  • Able to record CO, CO2, HCHO, TVOC, NH3, H2S, Temperature, Humidity, and Dew Point Measurements
  • Non-dispersive Infrared (NDIR) CO2 Sensor
  • Electrochemical Sensor
  • 2.8" LCD Touch Screen
  • Up to 450,000 records with date and time stamps
  • Touch-screen and Web-based Configuration Interface
  • Simple and Powerful Software Utility, iOS APP and Android App Included
  • Able to Display Multilingual Messages on the Screen
  • Supports the DCON, Modbus RTU, and MQTT Protocols
  • Includes RS-485/Ethernet/PoE Communication Interfaces
  • Relay Output for Audible/Visual Alarm or IAQ Device Control
  • Includes redundant power inputs: PoE (IEEE 802.3af, Class 1) and DC input
  • IP 65 Protection Approval

 

The DL-300-IP65 series of Data Logger devices can be used to record CO, CO2, HCHO, TVOC, NH3, H2S, Temperature, Humidity and Dew Point information, including date and time stamps, and are able to store up to 450,000 downloadable records. Real-time data can be accessed from the DL-300-IP65 series Data Logger from anywhere and at any time using the free Windows software, the iOS App or the Android App, as long as they are connected to the same local network as the Data Logger. Support is provided for popular industrial protocols such as DCON, Modbus RTU, as well as the emerging machine-to-machine (M2M)/IoT (Internet of Things) connectivity protocol-MQTT.

 

The DL-300-IP65 series Data Logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, and is easy to be maintained in a distributed control system. The IP65 version of DL-300-IP65 series is designed for industrial applications in harsh environments that provides IP65 grade protection approval. The rugged RJ-45 ensures tight, robust connections, and guarantees reliable operation, even for applications that are subject to high vibration and shock.

Large 2.8" LCD Touch Screen, with clear Color Chart to indicate the CO/CO2 Level   Supports the MQTT Protocol for IoT Applications
 
     
Simple and powerful utility
The DL300 Utility can be used to configure the modules, monitor real-time data, group DL-300 modules so that the status of distribution groups can be viewed and managed. The utility also allows the log data to be downloaded and exported to a .CSV file that can then be imported into any industrystandard software or spread sheet for analysis.
 
Multi-platform Remote Access Software
Real-time data from the DL-300 Data Logger can be accessed from anywhere and at any time using the DL300 Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the Data Logger.
 
     
Display Messages in Multiple Languages  
The display-message-on-screen function supports multiple language character sets based on UTF-8 encoding. Either pre-configured messages or dynamic messages can be remotely displayed using Modbus commands, or a dynamic message can be sent via the web-based interface.
 

Applications

Mushroom Farm
Mushroom growth yield requires long time to monitor the environment of CO2 concentration, temperature and humidity values, and its growth environment is high humidity condition. The general equipment cannot work in such environment, but the DL-302-IP65 can be used to record CO2, temperature, humidity and dew point information with date and time stamps in the operating temperature from -20?C to +50?C, and are able to store up to 450,000 downloadable records. The WISE-5231-3GWA features timer and schedule functions. It allows user to schedule specific date or time for control logic execution, or perform specific tasks such as time delay. With calendar user interface provided, schedule setting can be more efficient and flexible. This does not require programming, only some simple settings will be able to achieve the farm production control and quality control, production resume ... and so on.
 
 
Pig Farm
Ammonia and Hydrogen sulfide are two of the most harmful gases in animal farming environment. They will directly affect animals’ growth and immunity. Pig farm requires long-term immediate monitoring the environment of NH3 concentration, temperature and humidity values. The general equipment cannot work in such environment, but the DL-305-IP65 can be used to record NH3, temperature, humidity and dew point information with date and time stamps in the operating temperature from -20°C to +50°C, and are able to store up to 450,000 downloadable records. The WISE-5231-3GWA features timer and schedule functions. It allows user to schedule specific date or time for control logic execution, or perform specific tasks such as time delay. With calendar user interface provided, schedule setting can be more efficient and flexible. This does not require programming, only some simple settings will be able to achieve the farm production control and quality control, production resume ... and so on.

Specifications

Models DL-301-IP65 DL-302-IP65 DL-303-IP65 DL-304-IP65 DL-305-IP65 DL-306-IP65 DL-307-IP65 DL-308-IP65
System
CO Alarm Yes Yes
CO2 Alarm Yes Yes
HCHO Alarm Yes Yes
TVOC Alarm Yes Yes
NH3 Alarm Yes
H2S Alarm Yes
RH/Temperature Alarm Yes
Real Time Clock Yes
Data Logger Yes, up to 450,000 records
Relay Output PhotoMos Relay × 4, 100 VDC @ 1 A
Communication
RS-485 Port Baud Rate = 1200 ~ 115200 bps
Ethernet Port 10/100 Base-TX, 8-Pin RJ-45 x1(Auto-negotiating, Auto-MDI/MDIX, LED indicators)
Security IP filter (whitelist) and Password (web)
Protocol Modbus RTU(RS-485), MQTT(Ethernet)
Dual Watchdog Yes, Module (2.3 sec), Communication (Programmable)
LED Indicators
PWR Green for normal operation
Link Green for the Ethernet-linked
S1 ~ S4 Red for an alarm condition
Main Machine Interface
LCD 2.8 TFT (Resolution 240 x 320 x 16), Defective Pixels <= 3
Backlight Life 20,000 hours
Brightness 160 cd/m2
Touch Panel Yes
Electrical
Powered from Terminal Block +12 to +48 VDC
Powered from PoE IEEE 802.3af, Class 1 (48 V)
Power Consumption PoE 2.9 W (Max.) 3.0 W (Max.) 3.1 W (Max.) 2.0 W (Max.) 2.9 W (Max.) 2.9 W (Max.) 2.1 W (Max.) 2.0 W (Max.)
Non-PoE 2.7 W (Max.) 2.8 W (Max.) 2.8 W (Max.) 2.0 W (Max.) 3.0 W (Max.) 3.0 W (Max.) 2.1 W (Max.) 2.0 W (Max.)
Mechanical
Installation DIN-Rail or Wall Mounting
Dimensions (L x W x H) 170 mm x 211 mm x 60 mm
Environment
Operating Temperature -20 to +50°C
Storage Temperature -30 to +75°C
Humidity 10 to 90% RH, Non-condensing
Protection Class IP65

I/O Specifications

Models DL-301-IP65 DL-302-IP65 DL-303-IP65 DL-304-IP65 DL-305-IP65 DL-306-IP65 DL-307-IP65 DL-308-IP65
CO Measurement
Range 0 to 1000 ppm
(Electrochemical)
0 to 1000 ppm
(Electrochemical)
Resolution 1 ppm 1 ppm
Accuracy ±5% of 
measured value
±5% of 
measured value
Response Time 30 sec 30 sec
Warm-up Time 300 sec 300 sec
CO2 Measurement
Range 0 to 9999 ppm (NDIR)
Resolution 1 ppm
Accuracy ±30 ppm ±3% of measured value
Response Time 20 sec
Warm-up Time 60 sec
HCHO Measurement
Range 0 ppb to 2000 ppb
(Electrochemical)
0 ppb to 2000 ppb (Electrochemical)
Resolution 1 ppb 1 ppb
Accuracy 0 ~ 300ppb :
±30ppb >
300ppb : ±10%
0 ~ 300ppb :
±30ppb >
300ppb : ±10%
Response Time ≤60 sec ≤60 sec
Warm-up Time 180 sec 180 sec
TVOC Measurement
Range 0 ppb to 60000
ppb (MEMS
Metal Oxide)
0 ppb to 60000
ppb (MEMS
Metal Oxide)
Resolution 1 ppb 1 ppb
Accuracy ±15% ±15%
Response Time 60 sec 60 sec
Warm-up Time 180 sec 180 sec
NH3 Measurement
Range 0 to 100 ppm
(Electrochemical)
Resolution 1 ppm
Accuracy ±5% of
measured value
Response Time < 40 Sec
Warm-up Time 60 Sec
H2S Measurement
Range 0 to 100 ppm
(Electrochemical)
Resolution 1 ppm
Accuracy ±5% of
measured value
Response Time < 30 Sec
Warm-up Time 60 Sec
Temperature Measurement
Range -20 to +50°C
Resolution 0.1°C
Accuracy ±0.6°C
Relative Humidity Measurement
Range 0 to 100% RH, Non-condensing
Resolution 0.1% RH, Non-condensing
Accuracy ±5% RH, Non-condensing