M-7000 Analog

Voltage & Current Input
Model Input Channels Sampling Rate Voltage & Current Input Common Voltage Over Voltage Protection Resolution Price
M-7017 8 10 Hz ±150mV - ±10V
±20 mA ***
- ±35V 16-bit
M-7017C 8 10 Hz 0 - 20 mA
4 - 20 mA
±20 mA ****
±15VDC - 16-bit
M-7017R 8 10/60 Hz ±150mV - ±10V
±20 mA ***
- ±35V 16/12-bit
M-7017R-A5 8 10/60 Hz ±50V ±150V DC - 200 Vdc 16/12-bit
M-7017RC 8 10/60 Hz 0 - 20 mA
4 - 20 mA
±20 mA ****
+/200VDC ±35V 16/12-bit
M-7017Z 10/20 10/60 Hz ±150mV - ±10V
±20 mA ***
- ±240 Vrms 16/12-bit
M-7018 8 10 Hz ±15mV - ±10V
±20 mA ***
- ±35V 16-bit
M-7018R 8 10 Hz ±15mV - ±2.5V
±20 mA ***
- ±240 Vrms 16-bit
M-7018Z 10 10 Hz ±15mV, ± 50mV , ± 100mV, ± 500mV, ± 1V, ± 2.5V, ±20 mA *** - ±240 Vrms 16-bit
M-7019R 8 10 Hz ±15mV - ±10V
±20 mA
- ±240 Vrms 16-bit
M-7019Z/S 10 10 Samples/Sec +/- 15mV, +/- 50mV, +/- 100mV, +/- 150mV
+/- 500mV, +/- 1V, +/- 2.5V, +/- 5V,+/- 10V
-20 mA ~ +20 mA, 0 ~ 20 mA, 4 ~ 20 mA
+10 ~ +30 VDC 240 Vrms 16-bit
M-7019Z/S2 10 10 Samples/Sec +/- 15mV, +/- 50mV, +/- 100mV, +/- 150mV
+/- 500mV, +/- 1V, +/- 2.5V, +/- 5V,+/- 10V
-20 mA ~ +20 mA, 0 ~ 20 mA, 4 ~ 20 mA
+10 ~ +30 VDC 240 Vrms 16-bit
* Can be used as DI or low speed (50 Hz) counter.
** Can be used as DO or High/Low Alarm.
*** Needs external 125 Ω resistors.
**** Doesn't need external 125 Ω resistors.


Thermocouple Input
Model Input Channels Digital I/O Channels Sampling Rate Voltage & Current Input Sensor Input Over Voltage Protection Resolution Price
M-7011 1 - 10 Hz ±15mV, ±50mV, ±100mV,± 500mV , ±1V,± 2.5V
± 20mA ***
J, K, T, E, R, S, B, N, C ±35V 16-bit
M-7011D
M-7018 8 - 10 Hz ±15mV -
±2.5V
±20 mA ***
J.K.T.E.R.S.
B.N.C
±35V 16-bit
M-7018R 8 - 10 Hz ±15mV - ±2.5V
±20 mA ***
J.K.T.E.R.S.
B.N.C
Thermocouple
±240Vrms 16-bit
M-7018Z
(High Accuracy)
10 - 10 Hz ±15mV - ±2.5V
±20 mA ***
J.K.T.E.R.S.
B.N.C.L.M.
DIN43710
±240Vrms 16-bit
M-7019R 8 - 10 Hz ±15mV -
±10V
±20 mA
J.K.T.E.R.S.
B.N.C.L.M.
DIN43710
±240Vrms 16-bit
* Can be used as DI or low speed 100 Hz counter
** Can be used as DO or Alarm.
*** Needs external 125 Ω resistor


RTD Input
Model Input Channels Sampling Rate Sensor Input OVerVoltage Protection Resolution Individual Channel Configurable Price
M-7015 6 12 samples/second Pt100,
Pt1000,
Ni120,
Cu100,
CU1000
±5V 16-bit Yes
M-7015P 6 12 samples/second Pt100, Pt1000, Ni120, Cu100, Cu1000 ±5V 16-bit Yes
M-7033 3 15/12.5 samples/second Pt100,
Pt1000,
Ni120
±5V 16-bit -
M-7033D


Strain Gauge
Model Resolution Input Channel Sampling Rate Voltage &
Current Input
Sensor Input Input Linear Scaling Over Voltage Protection Digital I/O Price
16-bit 2 diff. 10Hz for 1-channel mode, 2Hz for 2-channel mode ±15mV
±50mV
±100mV
±500mV
±1V
±2.5V
±20mA
4 Wire Strain Gauge Yes ±5V 1 DI *
4 DO **
* Can be used as DI or low speed (50Hz) counter.
** Can be used as DO or Alarm.


Frequency Input / Counter
Model Input Channels Input Frequency Isolation Voltage Counter Input Digital Output Channels Output Voltage Output Current Price
M-7080 2 * 1 Hz to 100 KHz 3750Vrms 32bit 2 30V max 30 mA max
M-7080B 2 * 1 Hz to 100 KHz 3750Vrms 32bit 2 30V max 30 mA max
M-7080BD 2 * 1 Hz to 100 KHz 3750Vrms 32bit 2 30V max 30 mA max
M-7080D 2 * 1 Hz to 100 KHz 3750Vrms 32bit 2 30V max 30 mA max
M-7088-G/S 8* 1 Hz to 500 KHz - 32bit 2 50V max 200 mA max
                 
* Isolated or Non-Isolated


Thermistor Input
Model Input Channels Digital Output Channels Sampling Rate Sensor Input Over Voltage Protection Resolution Price
M-7005 8 6 * 8 Hz Precon ST-A3,
Fenwell U,
YSI L100,
YSI L300,
YSI L1000,
YSI B2252,
YSI B3000,
YSI B5000,
YSI B6000,
YSI B10000,
YSI H10000,
YSI H30000,
User-defined
+/-110VDC 16-bit
* Can be used as DO or High/Low Alarm.



Analog Output
Model Output Channels Voltage Output Power On Preset Current Output SafeValue (When Communication Fails) Resolution Power Consumption Price
M-7022 2 * 0-10V Yes 0-20 mA
4-20 mA
Yes 12-bit 3.0W
M-7024 4 ±10V,
0-10V,
±5V, 0-5V
Yes   No 14-bit 2.4W
* Channel to Channel Isolation
ICP DAS USA,Inc.